Dosimetry Performances of a MultiWell-Plate-Based Near-Field RF Applicator for the Investigation of EM Impact on Biological Cells - LAAS - Laboratoire d'Analyse et d'Architecture des Systèmes
Communication Dans Un Congrès Année : 2022

Dosimetry Performances of a MultiWell-Plate-Based Near-Field RF Applicator for the Investigation of EM Impact on Biological Cells

Résumé

While electromagnetic fields are now quasiubiquitous on earth and are constantly growing in use, RF radiation impact on living beings still continues to question. Within this context, a near-field RF applicator compatible with routine in vitro microplates for cellular investigations is proposed. This paper specifically focuses on its dosimetry performances, which are evaluated through simulation and measurements at 225 MHz, and its facility in biological postanalysis enabled by the use of standard bio-microplates.
Fichier principal
Vignette du fichier
IMS2022_Paper_expo RF complet.pdf (441.83 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03713378 , version 1 (04-07-2022)

Identifiants

Citer

Ali Moscatiello, Benjamin Cerdan, Camille Gironde, Christophe Furger, David Dubuc, et al.. Dosimetry Performances of a MultiWell-Plate-Based Near-Field RF Applicator for the Investigation of EM Impact on Biological Cells. IEEE MTT-S International Microwave Symposium (IMS 2022), Jun 2022, Denver, United States. ⟨10.1109/IMS37962.2022.9865593⟩. ⟨hal-03713378⟩