In-Situ and Contactless Evaluation of Performance of Power Converter EMC Filter based on Near-Field Scan Measurement - LAAS - Laboratoire d'Analyse et d'Architecture des Systèmes
Communication Dans Un Congrès Année : 2023

In-Situ and Contactless Evaluation of Performance of Power Converter EMC Filter based on Near-Field Scan Measurement

Résumé

This paper presents and validates an original contactless near-field scan-based method to quantify the performance of EMC filter mounted on power converter boards. The proposed method provides indicators about EMC filter attenuation, decoupling capacitor efficiency and differential-mode to common-mode conversion and may help designer to clarify and debug conducted emission issues of power converter boards.
Fichier principal
Vignette du fichier
Boyer_EMCEurope23_CE_filter_NF_eval_Final_correct.pdf (711.47 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04227850 , version 1 (04-10-2023)

Identifiants

  • HAL Id : hal-04227850 , version 1

Citer

Alexandre Boyer, Sonia Ben Dhia, Sébastien Serpaud. In-Situ and Contactless Evaluation of Performance of Power Converter EMC Filter based on Near-Field Scan Measurement. EMC Europe 2023, Sep 2023, Cracovie (PL), Poland. ⟨hal-04227850⟩