Under Voltage Lock-Out Design Rules for Proper Start-Up of Energy Autonomous Systems Powered by Supercapacitors - LAAS - Laboratoire d'Analyse et d'Architecture des Systèmes
Article Dans Une Revue Journal of Physics: Conference Series Année : 2013

Under Voltage Lock-Out Design Rules for Proper Start-Up of Energy Autonomous Systems Powered by Supercapacitors

Résumé

This paper deals with the issue of the initial start-up of an autonomous and battery-free system powered by an energy harvester associated with a storage subsystem based on supercapacitors initially discharged. A review of different low power Under Voltage Lock-Out (UVLO) solutions used to delay the load start-up and to avoid a useless discharge of supercapacitors is presented and discussed.
Fichier principal
Vignette du fichier
powermems_2013.pdf (836.82 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02042669 , version 1 (20-02-2019)

Identifiants

Citer

Vincent Boitier, Paul Durand Estèbe, Romain Monthéard, Marise Bafleur, Jean-Marie Dilhac. Under Voltage Lock-Out Design Rules for Proper Start-Up of Energy Autonomous Systems Powered by Supercapacitors. Journal of Physics: Conference Series, 2013, 476 (1), pp.012121. ⟨10.1088/1742-6596/476/1/012121⟩. ⟨hal-02042669⟩